Multilevel Inverter with Reduced Number of Switches and Reduction of Harmonics and topologies, modulation, voltage balance, comparison. Optimization of proposed MLI with a constant number of DC voltages sources for a maximum number of level. The Multilevel Inverter can also be used in ambulance or l
Single Phase Cross Switch Multilevel Inverter for Ambulance Equipment
Multilevel Inverter with Reduced Number of Switches and Reduction of Harmonics and topologies, modulation, voltage balance, comparison. Optimization of proposed MLI with a constant number of DC voltages sources for a maximum number of level. The Multilevel Inverter can also be used in ambulance or life saving equipments where the high output power required from medium voltage source of medical equipments so it can turn DC to AC in higher amount which increase the efficiency and competence of equipments
The main objective of this project are :
The cross-switch MLI was constructed by synthesize an interface between software and a number of hardware components. The components are cross-switch inverter, TMS320F28335 digital signal processor (DSP), DC sources and gate drivers. The generated signals from DSP transferred to gate driver’s circuit to 11 switches on the multilevel inverter. The DSP output was used to generate the results.
The design and implementation of the cross-switched multilevel inverter was clearly explained and the analysis between the proposed topology and other topologies has been demonstrated which helped assessing the importance of cross-switched inverter over other MLI’s. Furthermore performance, efficiency and harmonization of the inverter were validated by (NLC) Nearest Level Control the modulation techniques is used .Thus, the study shows that the output results in terms of frequency, total harmonic distortion and output voltage were very similar as well as perfectly matches with the results achieved from simulated and hardware model.
The primary purpose of inventing this new inverter topology was to eliminate their Harmonics.
This is economically affordable, Easy to install in all Ambulances and also compact and portable.
| Item Name | Type | No. of Units | Per Unit Cost (in Rs) | Total (in Rs) |
|---|---|---|---|---|
| Diode, Flying, capacitor, Stacked (MLI), Assymetrical CHB | Equipment | 1 | 7000 | 7000 |
| DSP and DCS Controller | Equipment | 1 | 9000 | 9000 |
| IGBT Switches | Equipment | 1 | 4000 | 4000 |
| Gate Drivers | Equipment | 1 | 5000 | 5000 |
| Soldering Kit and PCB pter, | Equipment | 1 | 7000 | 7000 |
| Multimeter | Equipment | 1 | 4000 | 4000 |
| Fluke 43B | Equipment | 1 | 7000 | 7000 |
| Display Prototype | Miscellaneous | 1 | 4000 | 4000 |
| Protection Circuit | Equipment | 1 | 4000 | 4000 |
| Power Module | Equipment | 1 | 15000 | 15000 |
| Fire extinguisher | Miscellaneous | 1 | 3000 | 3000 |
| Hand Gloves | Miscellaneous | 1 | 2000 | 2000 |
| Safety Helmet | Miscellaneous | 1 | 1000 | 1000 |
| Motor | Equipment | 1 | 8000 | 8000 |
| Total in (Rs) | 80000 |
This is a dual-purpose Trolley. Which can be used as a normal trolley as well as on the St...
Automatic phase correction and protection devices Due to power fluctuation and load sheddi...
IVSA is security system aimed to design for building security. Buildings include shopping...
One of the major challenges with electrical power systems is preserving the survivability...
Our E-plantation system is consisting of two phases. In the first phase, we design the sys...